fixing screws (Fig.7c).
- check and if necessary act on the ultrasonic
sensor support until obtaining the required
distance between the calibration template
and the support itself (Fig.7d), proceeding
as follows:
1. Fix the calibration jig of the ultrasonic sen-
sor in the kit to the shaft of the oscillating
unit using the centering accessories;
2. Lower the wheel guard;
CAUTION
Lowering the wheel protection enables the
launch of the oscillating unit with the tem-
plate locked !!!
3. Align the calibration gauge of the ultrasonic
sensor with the ultrasonic sensor holder
and check the distance using a meter, ie:
a. 270mm (tolerance +/- 5mm)
IMPORTANT: after installing the ultrasonic
sensor, calibrate the sensor as described
in the paragraph "Calibrating ultrasonic
width measuring sensor".
After installing the machine, move into the
selected location, ensuring that the spaces surrounding the machine comply with the
minimum dimensions indicated in Fig. 5a.