To change the application position for the adhesive
weights, follow the instructions in the set up menu
"Adhesive weight application position ".
• Manually applied adhesive weights with laser
device enabled (if provided)
1 Select the first side to be balanced.
2 Turn the wheel until the central element of
the corresponding position indicator lights up
together with the laser line.
3 Apply the adhesive weight manually in the posi-
tion in which the relative plane was measured,
using the centre of gravity of the weight itself as
reference. In this phase, one display shows the
unbalance value of the side to be balanced and
the other shows the message "H.6" that indicates
the correct position of application as shown in
figure 19.
• Adhesive weights applied manually without the
weight-holder device (CLIP adhesive weight
application position enabled)
1 Select the first side to be balanced.
2 Turn the wheel until the central element of the corresponding position indicator lights
up. Keeping the wheel in position with the clamping brake, a display will now show the
quantity of the weight to be applied in gr/ounces and the other will display the distance
in mm alternatively to the plane identification abbreviation (A-1 for Inner Plane/A-2 for
Outer Plane).
3 IN THE MACHINE VERSION WITH AUTOMATIC SENSOR move the sensor until it
reaches the indicated position. During this phase, the unbalance value of the side to be
balanced is shown on one display, whereas the numerical value updated according to
the sensor position, which becomes zero when the position for application of the weight
is reached, is shown on the other display.
IN THE MACHINE VERSION WITH MANUAL SENSOR with the wheel in a centred
position, the machine indicates the unbalance value on a display, whereas the other
display shows the message "d1" or "d2" alternately to the distance value of the plane
corresponding to the body.
Move the sensor to the position shown on the display in which the message "d1" or "d2"
appears alternately to the distance value (the distance is read on the rule)
4 Apply the adhesive weight manually, using the centre of the notch in the holder as the
reference for the centre line of the weight.
"Shift planes" programme (only with ALU P programmes)
This function is automatically enabled when an ALU P programme is selected.
It modifies the former selected positions for the application of adhesive balancing weights,
in order to allow perfect wheel balancing using commercially available adhesive weights
in multiples of five grams.
118
EM 9250 - EM 9250 C CompactLine Operator's manual
19