7

Installation

7.1
Actuator mounting on the
valve body
6
1. Move the actuator A to the open position.
2. Insert the gasket 30 into the valve
body 1.
3. Place the actuator A and seat fl ange 29
on the valve body 1 approx. 90°
anticlockwise to the desired end position
of the control medium connectors.
4. Ensure that the hole patterns of the seat
fl ange 29 and valve body 1 are aligned.
5. Tighten the hexagon nut 6 diagonally.
6. With the valve fully assembled, check
that it is working correctly and that it is
leak-tight.
532 SVS
8
A
29
30
1
16 / 20

Disposal

Dispose of all parts in ac-
G
cordance with disposal
regulations/environmental
protection laws.
Pay attention to adhered
G
residual material and gas
diff usion from penetrated
media.