3.5.3
Connection panel FSA 500
DANGER – Risk of electric shock from ex-
cessively high measurement voltage!
The measurement of voltages in excess of
200 V using CH1 / CH2 multi measurement
cables will result in injury, heart failure or
fatal electric shocks.
¶
CH1 / CH2 multi measurement cables are
only to be used for measuring voltages up
to max. 200 V.
¶
Never use CH1 / CH2 multi measurement
cable to measure mains or similar volta-
ges.
459903-02_Ko
1
2
3
4
5
Fig. 2:
Connection panel FSA 500 (viewed from underneath)
Item
Color code
Connection
1
Red/black
Battery B+/B‒ cable
(battery B– cable for vehicle
ground)
2
Green or
Secondary measuring sensor or 30 A
white or yel-
amps clamp or 1000 A amps clamp
low
or adapter cable 1 681 032 098 with
fluid pressure sensor (both special
accessories)
3
Green or red
CH2 multi measurement cable
or yellow
or 30 A amps clamp or
1000 A amps clamp
4
Green or blue
CH1 multi measurement cable
or yellow
or 30 A amps clamp or
1000 A amps clamp
5
-
Coupling with hose assembly (at-
mospheric pressure measurement)
6
-
Remote trigger
7
White/black
Clip-on sensor or adapter cable
1 684 465 513 for clip-on sensor1)
8
Blue/white
Oil temperature sensor, air and IR
temperature sensor (special acces-
sories)
9
Yellow / green Connecting cable term. 1/term.
15/EST/TN/TD
10
-
Power supply port
11
-
-
Connection for charging station
(special accessory)
For speed measurements with a clip-on sensor, the adapter cable
1)
1 684 465 513 must always be connected between the FSA 500
socket (item 7) and the connection cables for the clip-on sensor.
The color codings on the connection cables refer to the correct
2)
connection at the FSA 500.
Robert Bosch GmbH
6
7
8
9
10
11
2)
Product description | FSA 500 | 23
3.5.4
LED Indicators
LED A: Status light
State
LED A
Not lit
FSA 500 off.
Red light
The FSA 500 starts up.
Flashing
FSA 500 on, but not yet ready for operation.
white
No data link with PC/Laptop.
(1 Hz)
Flashing
FSA 500 is ready for operation.
green
Data link to PC/Laptop established via USB.
(1 Hz)
Flashing
FSA 500 is ready for operation.
blue
Data link to PC/Laptop established via Bluetooth.
(1 Hz)
Flashing
Firmware error.
red
FSA 500 not ready for use.
(4 Hz)
LED B: Charge indicator
State
LED B
Not lit
No external power sup-
ply connected. Voltage
supply via battery.
Violet light
External voltage sup-
ply connected. Storage
battery being charged.
Blue light
External voltage sup-
ply connected. Storage
battery is charged.
Red light
External voltage supply
connected.
Possible cause of trou-
ble:
R Battery temperature
>45 °C
R Storage battery not
connected
R Battery defective
R Plug defective
3.5.5
Remote trigger
The start soft key (F3) or the stop soft key (F4) in the
FSA 500 CompacSoft [plus] software can be activated
with the button on the remote trigger.
2
Fig. 3:
Remote trigger (1 684 463 828)
1 Key
2 Connector for FSA 500
i
For connection see fig. 2, item 6.
en
Measure
-
-
External voltage supply
can be disconnected.
Check storage battery
and plug.
Allow the FSA 500 to
cool down.
1
459903-04_Ko
|
1 689 989 411
2019-04-01