Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Genius LYNX 06 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für LYNX 06:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 63
OPERATING INSTRUCTIONS – INSTALLATION INSTRUCTIONS
The LYNX 06control units are designed and built for managing electro – mechanical barriers for controlling residential
accesses.
The two models differ in their voltage:
Lynx 06: Power supply 230V
Lynx 06: Power supply 115V
Thanks to their wide ranging number of selectable parameters, these control units can be adapted to your requirements
guaranteeing optimal operation of the automated system.
The possibility of managing an encoder for detecting any obstacles enables you to further increase the safety level
of the automated system.
Programming the main operating parameters is done by pressing two keys on the control unit and is shown on the
generous back lit display. During normal operation, the display shows the status of the automated system at all times.
Learning the work cycle and the mechanical stop-points is performed automatically while the first cycle is being
performed (whenever power is cut, the control unit searches the stop-points both at opening and closing).
The six integrated LEDs constantly indicate the inputs status.
Supply voltage of control unit
Absorbed power
Motor absorbed power
Accessories max. load
Power supply and indicator light max. load
Power supply and max load of barrier status indicator light
Operating ambient temperature
Protective fuses
Function logics
Opening / closing time
Pause time
Motor power
Slow-down time
Obstacle detection
Selectable functions
Terminal board inputs
Inputs with connector
Terminal board outputs
Board dimensions
According to board model, 230 Vac or 115 Vac.
a
To ensure people's safety, all warnings and instructions in this booklet must be carefully observed. Incorrect
installation or incorrect use of the product could cause serious harm to people.
Keep the instructions for future reference.
Make sure that an adequate differential switch is installed upstream of the system as specified by current safety
regulations.
On the main power supply, install a thermal breaker with omnipolar switching.
Make sure that an adequate earthing system is available.
To lay cables, use adequate rigid and/or flexible tubes.
Always separate the 230/115 Vac power cables from low voltage connections, using separate sheaths to avoid
possible interference.
CONTROL UNIT FOR BARRIERS
. DESCRIPTION

2. TECHNICAL SPECIFICATIONS

Automatic / Step-by-step automatic /Semiautomatic
Nine levels selectable up to a maximum of 4 minutes
Operates with or without encoder / Encoder sensitivity/
function / Slow-down percentage/ Heating function /
Immediate closure / Timer function / Soft start / Photocells
Opening / Closure / Photocells / Opening travel limit
device /Closure travel limit device / Stop / Mains power
Power supply to accessories / Flashing lamp / Motor /
3. PREPARATORY ACTIONS
7
230/115 Vac 50/60 Hz
3 W
500 W
500 mA
230 Vac 25 W
24 Vdc 5 W
-20°C +55°C
F1= T5A (Transformer and motor primary winding)
F2= T500mA (accessories and indicator light)
/Step-by-step semiautomatic / Condo
In self learning mode during first manoeuvre
Adjustable on several levels
Three selectable levels
With optional encoder
Automatic closure / Open input operation/Condo
operation /Maintenance request
supply / Earthing
Radio module / thrust capacitor / encoder
Indicator light
147 x 112 mm
a

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis