Technical data
9.2
Resistance to penetration of infectious
agents
Test
Resistance to
contaminating liquids under
hydrostatic pressure
(with the Phi-X174
bacteriophage)
1
according to EN 14126:2003+AC:2005
9.3
Resistance of the suit material
Test
Abrasion resistance
Flex-cracking resistance
Flex-cracking resistance at
2
-30 °C
Tear resistance
Bursting strength
Puncture resistance
Resistance to flame
penetration
Seam strength
Tensile strength
1
according to EN 943-1:2015
2
according to EN 14126:2003+AC:2005
3
according to EN 1073-1:2016+A1:2018 and EN 1073-2:2002:
Class 2
32
Result
Category
hydrostatic
6
pressure:
20 kPa
Result
Class
>2000 cycles
6
>100000 cycles
6
>4000 cycles
6
>60 N
4
643 kPa
5
>50 N
3
3
self-extinguishing
fulfilled
>500 N
6
>1000 N
6
1
1
Dräger CPS 6900