EN
Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain con-
densate from valve(s) at low point(s) of piping, air filter and compressor tank daily. Install a prop-
erly sized Safety Air Fuse upstream of hose and use an anti-whip device across any hose coupling
without internal shut-off, to prevent hose whipping if a hose fails or coupling disconnects. M2
Series vanes are made of a special material that does not require constant lubrication. However,
we do suggest periodic lubrication for optimum service life. See drawing 47504314001 and
table on page 2. Lubrication volume listed for the angle head is approximate. For best
results, remove the screw plug opposite the grease fitting, inject lubrication through the
grease fitting until fresh grease is observed in the screw hole, then reinstall the screw
plug. Maintenance frequency is shown in a circular arrow and defined as h=hours, d=days, and
m=months of actual use. Items identified as:
1. Air filter
2. Regulator
3. Emergency shut-off valve
4. Hose diameter
5. Thread size
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
Original instructions are in English. Other languages are a translation of the original instructions.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Office or Distributor.
EN-2
6. Coupling
7. Safety Air Fuse
8. Grease
9. Grease
48420533_ed4