8. PROBLEMS
Some possible problems wich may arise while using the lift are listed below. Ravaglioli will not accept any resposibility
for damage people, animals and objects caused by unautorized staff using the equipment. In the event of faults, you are
advised to contact the technical service department in good time to receive advice about how to carry out work and/or
adjustments in maximum safety conditions, thus avoiding the risk of damage to people, animals and objects.
Turn the main switch to "0" and lock in case of emergency and/or maintenance to the lift.
TROUBLE
The lift does not
work
The lift rises but
does not lower
Lowering speed is
very low
The motor turns
regularly but the lift
does not rise, or
rises slowly
The lift lowers but
does not lift
70
POSSIBLE CAUSES
a)
Main switch in "0" position
b)
Fuse of the transformer or main
protection fuses (installed by the user)
burnt
c)
Failure in the electric installation
d)
Cable breakage safety limit switch with
open contacts (jammed, broken or
operated by malfunction in the driving
cam controls)
e)
Cable safety actuated due to very slack
cable
f)
Cable safety actuated due to broken
cable
g)
Disconnected motor thermal probe
a)
Slack cable safety actuated by obstacle
under the platform or by slack cable
b)
Malfunction of the system driving the
operating cam
c)
Failure of descent solenoid valve
a)
The flow controlvalve does not work
properly
b)
Clogged pipe
a)
Descent solenoid valve jammed in open
position
b)
Pump intake filter clogged
c)
Piston gasket damaged or worn
d)
Pump worn or damaged
a)
Rise limit switch with open contacts
(jammed or broken)
TECNICAL SERVICE REQUIRED
do not attempt to do the job yourself
a)
Turn the switch to "I" position
b)
Replace the burnt fuses. Should the
fuse burn again, find the cause of the
failure
c)
Check the efficiency of connections and
components (buttons, remote control
switch, transformer, thermal probe)
d)
Repair the limit switch taking care to
check the proper running of the control
system of the cam which operates the
safety limit switches. Replace the limit
switch if necessary
e)
Operate directly on the remote control
switch by means of an isulated
scewdriver until the cable is tensioned
f)
Replace the cable (ask for the
assistance of the after sales service of
your distributor)
g)
Wait for thermal probe to reconnect
a)
Press the rise button to tension all
cables. Remove the causes of cable
slackening, then lower the lift
b)
Repair the limit switch and check the
correct running of the control system of
the cam operating the safety limit
switch. Replace the switch if necessary.
c)
To lower the lift operate the manual
lowering valve using the proper key. For
disassembling of the lowering solenoid-
valve see MAINTENANCE
a)
Clean the valve (see § 7.5)
b)
Clean piston valve
a)
Clean the solenoid valve (see § 7.4)
b)
Clean the filter
c)
Replace the gasket
d)
Check pump for proper operation and
replace it if needed
a)
Repair the limit switch or replace it
0700-M001-0
REMEDIES
RAV4300-RAV4350-RAV4351
RAV4355-RAV4400-RAV4401
RAV4405-RAV4501-RAV4650-RAV4800