ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch
having a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.
• Fasten the Chimney fixing element 19 to the Body using 4
screws 12c.
Upper chimney
• Open the two side pieces out slightly, hook them up behind the
brackets 7.2.1 and bring them back together again until they
are in contact.
• Fix to the Brackets at the sides, using 4 screws 12c (2.9 x 9.5)
provided.
• If there are any, make sure that the Connector extensions outlet
is in correspondence with the Chimney openings.
Lower chimney
• Open the two side pieces of the Chimney out slightly, hook
them between the upper chimney and the wall, and then close
them together again until they are in contact.
• Fix the part at the sides to the Chimney fixing element 19,
using 2 screws 12c (2.9 x 9.5) provided.
EN
Chimney Assembly
1
10
0