During assembly
During commissioning
AVENTICS | DeviceNet | R402003659–BAL–001–AG
use a product in safety-relevant applications if such use is
specifically stated and permitted in the product documentation.
W
You may only commission the product if you have determined that
the end product (such as a machine or system) in which the
AVENTICS products are installed meets the country-specific
provisions, safety regulations, and standards for the specific
application.
2.6
Safety instructions related to the product and
technology
W
Do not place any mechanical loads on the device under any
circumstances. Do not place any objects on it.
W
Ensure that the power supply is within the stipulated tolerance for
the modules.
W
Observe the safety notes found in your valve system's operating
instructions.
W
Only use the following power supply for the bus coupler:
– 24 V DC PELV circuits in accordance with DIN EN 60204-1/
IEC 60204-1.
– The PELV power source must be a safety isolation transformer in
accordance with IEC 61558-1 or IEC 61558-2-6, or a power
source offering the same degree of safety as a safety isolation
transformer.
– Make sure that the power supply of the power pack is always less
than 300 V AC (outer cable – neutral wire).
W
Switch off the operating voltage before connecting or disconnecting
plugs.
W
The warranty only applies to the delivered configuration. The
warranty will not apply if the system is incorrectly assembled or
manipulated.
W
Make sure the relevant system component is not under pressure or
voltage before assembly or disassembly. Ensure that the system is
prevented from power restoration during assembly work.
W
Connect the modules and the valve system to functional earth (FE):
– Connection according to DIN EN 60204-1/IEC 60204-1
W
Installation may only be performed in a voltage-free and pressure-
free state and only by a qualified technician. In order to avoid
accidents caused by dangerous movements of the actuators,
electrical commissioning is to be carried out only in a pressure-free
state.
W
Do not put the system into operation before it is completely
assembled as well as correctly wired and configured, and after it
has been tested.
W
The device is subject to the restrictions of the IP65 protection class.
Before commissioning, make sure that all the connection seals and
57