Herunterladen Inhalt Inhalt Diese Seite drucken

AL-KO mammut Bedienungsanleitung Seite 16

Vorschau ausblenden Andere Handbücher für mammut:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
Table of fault numbers
The four LEDs on the operating and display unit are used to indicate faults and the charger status.
Operating status in the
case of a fault
LED colour
Battery is missing
Charger is not working
or too high an operating
voltage
Timing fault
Regulating fault
Temperature fault
The following table provides an overview of the possible causes of faults and how to rectify them:
Error number
Cause
1
Battery is missing
Battery poles reversed
Battery voltage < 3V
2
Charger is not charging
3
Battery voltage < 9V for longer than
30 minutes
4
Charging process is taking too long
5
Regulating limit value for voltage /
current exceeded
6
Temperature in the charger too high
16
Red
Green
X
X
X
X
X
X
LED display
Yellow
Yellow
Flashing
X
X
Corrective measure
Connect battery
Check whether the battery poles have been re-
versed
Battery is totally discharged; have the battery
checked by the AL-KO Service team, if necessary
Unplug the charger and plug it back in again
- Charger is still not charging → AL-KO Service
Unplug the charger and plug it back in again
Have the battery checked by the AL-KO Service
team
Unplug the charger and plug it back in again
Have the battery checked by the AL-KO Service
team
Unplug the charger and plug it back in again
Unplug the charger, disconnect the battery from the
charger and re-connect to the charger again. Plug
the charger in
Unplug the charger and plug it back in again
Check whether the charger's supply and exhaust air
is ensured
Check whether the ambient temperature is too high
Error number
1
2
3..4
5
6

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis