Type 8026 - 8036 - 8076
Technical data
7.
TECHNICAL DATA
7.1.
Conditions of use
Ambient temperature:
-10 à +60°C (operating)
Air humidity:
< 85%, non condensated
Protection rating:
IP67 and IP65 with connectors plugged in
and tightened and electronic module cover
fully screwed down
7.2.
Conforming to standards and
directives
7.2.1.
Conformities common to the 8026
and the SE36
•
EMC: EN 61000-6-2 (2005), EN 61000-6-3 (2001)
•
Vibration: EN 60068-2-6
•
Shock: EN 60068-2-27
And, for UL recognized devices (
of America and Canada, with variable key PE72:
•
UL 61010-1
•
CAN/CSA-C22.2 No. 61010-1
7.2.2.
8026 devices and S030 and S070 fittings comply with the require-
ments of Article 3 of §3 of the Pressure Directive.
According to Pressure Directive 97/23/EC, the product can only be
used in the following cases (depending on the max. pressure, pipe
diameter and the type of fluid):
Type of fluid
Fluid group 1 § 1.3.a
Fluid group 2 § 1.3.a
Fluid group 1 § 1.3.b
Fluid group 2 § 1.3.b
) in the United States
Conformity to the Pressure
Directive of 8026 transmitters and
S030 and S070 fittings
Conditions
•
8026 transmitter and S030 fitting:
≤
DN
25 only
•
S070 fitting: forbidden
DN ≤ 32
or DN > 32 and PNxDN ≤ 1000
•
8026 transmitter: DN
DN > 25 and PNxDN ≤ 2000
•
S030 and S070 fittings:
PNxDN ≤ 2000
•
8026 transmitter: DN
•
S030 and S070 fittings: DN
english
≤ 25 or
≤ 400
≤
200
7