DIP 14
DIP 15
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
DIP 17 ON
- close command after the transit through the photocell ENABLED
OFF
- close command after the transit through the photocell DISABLED
DIP 18 ON
- Working with motors 120V 60Hz
OFF - Working with motors 230V 50-60Hz
LED WARNINGS
DL1 - programming activated (red)
DL2 - stop contact NC (red)
DL3 - open limit-switch contact (red)
DL4 - close limit-switch contact (red)
DL5 - photocell contact (NC) (red)
DL6 - gate opening (green)
DL7 - gate closing (red)
DL8 - safety strip contact (NC) (red)
DL9 - Encoder output state
DL10 - radio code programming (green) (only for CRX)
FUSES
F1 T100mA
Fuse for accessories protection
F2 T5A
Fuse for motor windings protection
RELAYS AND MOTOR CONTROL
K1 => Opening command
K2 => Closing command
K3 => Flashing light command
Q5 => TRIAC - Motor command in opening and closing
TORQUE =>TR2 - Electronic regulator for motor torque
Power can be controlled by rotating the TORQUE trimmer – this changes the output voltage
on motor ends (more power is delivered to the motor by rotating the trimmer clockwise).
Actually, the motor is always turned on at full power regardless the trimmer position (to
guarantee the starting in all the condition) and, then, after 3seconds, the torque control is
activated.
LOW SPEED =>TR1 - Electronic regulator for low speed on approach
If DIP9 is turned OFF, the low speed on approach can be controlled by rotating the LOW
SPEED trimmer. The low speed is activated when the gate is 0.50-0.60 meters away from
the complete closed or open position.
ELECTRONIC BRAKE
If DIP 10 is turned ON, the electronic brake will activate upon total opening or closing.
ELECTRONIC BRAKE (For FAST operators)
If DIP10 is turned ON, a HARD electronic brake will be active.
If DIP10 is turned OFF, a SOFT electronic brake will be active.
GRADUAL START
If DIP11 is turned ON, a gradual movement will be enabled for 1second upon each starting.
In case of an obstacle is detected by any safety inputs (photocell, safety strip or encoder), the
gradual start is bypassed for the time being to guarantee a more prompt and safe reaction.
POINT C - MOTOR ROTATION DIRECTION CHECK
This operation is meant to help the installer during the installation and for further future
controls.
1 - Unlock the operator with the Manual Release, slide the leaf open about halfway and lock
the operator again.
2 - Turn DIP1 to ON position, LED DL1 starts blinking
3 - Press and hold the PROG.Button, the gate will open or close. Release the button and
the gate will stop. Press and hold again, the gate will move in the opposite direction.
The S1 control board has two movement leds
- DL6 the GREEN led for OPENING
CHART 1
DIP 16
MOTOR TYPE
OFF
K800 - K800 PLUS
ON
K800 FAST
OFF
K1400 - K1400 PLUS
OFF
K2200 - K2200 PLUS
OFF
SUPER 2200
ON
SUPER 2200 FAST
- DL7 the RED led for CLOSING
When you press and hold the PROG.Button, if the gate opens with the green led on then
you may proceed to step 4.
If the gate moves in the wrong direction compared with the movement leds:
- turn OFF the main AC power
- reverse the V and W motor cables position (the blue motor cable must be always in the
U position)
- reverse the limit switch wires marked LSO and LSC
- turn ON the main AC power and check again the motor direction
4 - After 3seconds (2 for FAST operator) motor starting and for the next 10 seconds (6 for
FAST operator) motor working, the torque control is automatically activated. Set the
motor torque by the TORQUE Trimmer which varies the output voltage to the head of the
motor (turn clockwise to increase torque).
5 - After other10 seconds (6 for FAST operator) motor working, the low speed control is
automatically activated (DIP9 OFF). Set the motor low speed by the LOW SPEED Trimmer
to select the gate leaf low speed in approaching.
6 - Press and hold the PROG.Button to close completely the gate. Turn DIP1 to OFF, the RED
led DL1 will stop blinking.
During Point C procedure, safety devices (photocells and safetystrip) are not active
and the remote control cannot operate.
(#) In Point D and Point E procedures, all of them will be active, so they must be properly
installed and connected to the control board. Any changing of the safety devices input state,
will stop the Point D and Point E procedure that must be repeated from the beginning.
POINT D - PROGRAMMING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PROG.Button, motor opens.
4 - Once reached the open position, the open limit switch will cut out motor and the gate
travelling will be stored. The gap of time between now (stop of motor) and the next
pressing of the PROG.Button (see step 5 below) will be then stored as waiting time for
Automatic Closing feature.
5 - Press PROG.Button, gate closes and the Automatic Closing time is stored (see DIP3
function to enable or disable the Automatic Closing feature).
6 - The LED DL1 will turn OFF, signalling exit from the Point D procedure.
Closing of the gate will be carried out at normal speed and only on approaching total
closing at low speed (depending on the adjustment of LOW SPEED trimmer).
7 - When the gate leaf reaches the close limit switch plate, the motor stops.
8 - Turn DIP2 to OFF position.
IN CASE OF PLUS OPERATORS EQUIPPED WITH ENCODER, THE DIP7 MUST BE TURNED ON
DURING THE PROGRAMMING PROCEDURES.
POINT E - PROGRAMMING OF PEDESTRIAN OPENING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts blinking slowly
4 - Press the pedestrian pushbutton PED.Button, the gate opens
5 - When the gate leaf is opened enough for the pedestrian crossing, press the pedestrian
pushbutton PED.Button to stop the travel (thus defining the opening stroke of the
motor). The gap of time between now (stop of the motor) and the next pressing of the
PROG.Button (see step 6 below) will be stored as waiting time for Pedestrian Automatic
Closing feature.
6 - Press the pedestrian pushbutton PED.Button, gate closes and the Pedestrian
Automatic Closing time is stored (see DIP3 function to enable or disable the Automatic
Closing feature).
7 - Turn DIP1 to OFF position
8 - Turn DIP2 to OFF position
POINT F - PROGRAMMING RADIO CODES FOR COMPLETE OPENING
(UP TO 62 CODES - ONLY FOR CRX MODELS)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press the remote control button (normally channel A) within the 10 seconds proscribed. If
the remote control has been correctly programmed, the DL10 LED (green) will flash once.
4 - The code programming time resets automatically so that you can programme the next
remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button briefly. The
red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 2 to OFF.
7 - You have completed the procedure