Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Kemper VacuFil 125 Betriebsanleitung

Schweißrauchfiltergerät
Vorschau ausblenden Andere Handbücher für VacuFil 125:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3

9.2 Technical data

Basic data
Extraction capacity
Minimum extraction performance
(threshold value volume flow monitoring)
Negative pressure
Motor output
Terminal voltage / rated current
Sound pressure level
Duty cycle
Type of protection
ISO Class
max. permissible ambient temperature:
Max. permissible humidity:
Filter
Filter stages
Filter process
Dust removal process
Filter surface
Filter type
Filter material
Separation efficiency:
dust class
Welding fume separation class
(according to EN ISO 15012-1)
1502649-00
Technical data
165 m³ / h (freely suctioning)
Depends on the welding fume extraction
burner selected.
Is smaller than the set specific suction
power of the selected welding fume
extraction burner.
27.000 PA
1.5 kW
See Identification Plate
66 dB(A)
100%
IP 21
F
-20 / + 40⁰C
85%
Technical data
2
Dust removal filter
Rotating nozzle
4 m²
Filter cartridge
ePTFE membrane
≥99.99%
M
W3
- 113 -