(3)
(3)
(2)
(1)
CAUTION!
The PCM paste must not be damaged or
removed when inserting the SymoPS DC
Insert the new SymoPS DC and positi-
2
on accordingly
NOTE!
To avoid applying mechanical stress to
the solar modules, apply the torque in
the same sequence
Fit the SymoPS DC solar modules with
3
four 4x9 TX20 screws (3). Observe the
torque sequence to avoid applying me-
chanical stress
First pretension all four screws to [0.5
Nm] and then tighten them to [2 Nm]
Thread in and connect all cables and
4
plug connections (1)
Fit the SymoPS DC with 13/15 4x9
5
TX20 screws (2)
[2 Nm]
NOTE!
Ensure that the ferrite cores and their
holders are fitted correctly
Close the inverter and place it in the
6
wall bracket (see "Opening and closing
the device" and necessary „Replacing
(1)
the Overvoltage PC board" sections)
Switch on the inverter and then carry out a
fan test via the display (see operating inst-
ructions)
163