Replacing the
Removing the Eco fuse:
Eco fuse
Installing the Eco fuse:
136
(2)
(2)
(2)
(2)
WARNING!
Observe the safety rules (see the begin-
ning of the "Safety" section)
(1)
Take the inverter out of the mounting
1
bracket and remove the Eco DC dis-
connector (see "Opening and closing
the device" and "Replacing the Eco DC
disconnector" sections)
Undo the three TX20 screws (1)
2
Undo the seven 4x12 TX20 screws (2)
3
and remove the Eco fuse
(2)
Insert the new Eco fuse and secure it
1
using seven 4x12 TX20 screws (2)
[1.5 Nm]
(2)
Tighten the three TX20 screws (1)
2
Insert the Eco DC disconnector, close
3
the inverter and place it in the moun-
ting bracket (see "Replacing the Eco
DC disconnector" and "Opening and
(1)
closing the device" sections)