Inserting the SymoPS AC:
160
(4)
(4)
NOTE!
Do not press on the marked area ->
this will damage the PCM material
Detach the blister packs from the new
1
SymoPS AC at the tabs and place
them on the faulty SymoPS AC
CAUTION!
The PCM paste must not be damaged or
removed when inserting the SymoPS AC
Insert the new SymoPS AC and positi-
2
on accordingly
NOTE!
To avoid applying mechanical stress to
the solar modules, apply the torque in
the same sequence
Fit the SymoPS AC solar modules with
3
six 4x9 TX20 screws (4). Observe the
torque sequence to avoid applying me-
chanical stress
First pretension all six screws to [0.5
Nm] and then tighten them to [2 Nm]