5.1.2 Valve structure Type 5470
Pilot valve
Type 6106
Exhaust port 3
Pressure inlet port 1
Working port 4
5.1.3 Valve structure Type 0470
Solenoid coil
Type AC27
Exhaust port 3
Pressure inlet port 1
Working port 4
6
TECHNICAL DATA
6.1 Conformity
The solenoid valve Type 0470, 5470 is compliant with EC directives
as stated in the EC Declaration of Conformity.
6.2 Standards
The applied standards which are used to demonstrate compliance with
the EC Directives are listed in the EC Prototype Examination Certificate
and/or the EC Declaration of Conformity.
6.3 Type label
Example:
Circuit function
Type
5470
G
G1/8
PN2–10bar
24V
DC
00203236
Order number
Fig. 1:
Example of type label on the pilot-controlled solenoid valve
Type 5470
6
Important information for functional reliability during continuous
operation!
If the equipment is switched off for a long period, it is recom-
mended to activate the valves at least 1-2 per day.
Service life:
High switching frequency and high pressures reduce the service life.
The valves operate maintenance-free.
6.5 Materials
Housing material: PA
Seal material:
NBR
Cable plug
Type 2506
Manual control
Working port 2
Cable plug
Type 1054
Working port 2
Orifice
4,0
Connection type,
permitted pressure range
2W
Voltage (± 10 %),
frequency,
output
W1YMG
Manufacturer code
english
5.2 Circuit functions
C
3/2-way valve
Normally inlet port 1 closed, working port 2
connected with exhaust port 3.
D
3/2-way valve
Normally inlet port 1 connected with working
port 2, exhaust port 3 closed.
G
4/2-way valve
B
Normally inlet port 1 connected with working
port 2, working port 4 connected with exhaust
P R
port 3.
english
6.4 Operating conditions
Please observe the specifications on the data sheet and on
the type label.
Ambient
–10 °C ... +55 °C (please observe temperature
temperature
restrictions on account of approvals)
Permitted
–10 °C ... +50 °C
medium temp.
Compr. air quality ISO 8573-1:2010, Class 7.4.4
Permitted media Filtered compressed air oiled and unoiled, neutral
gases
Permitted
Observe specifications on type label
pressure range
Pressure difference at least 2 bar between
ports 1 and 3
Degree of
IP65 as per DIN EN 60529 / IEC 60529 with
protection
correctly connected and fitted cable plug,
e.g. Bürkert Type 2506
Operating
Unless otherwise indicated on the type label, the
duration
solenoid system is suitable for continuous operation
To prevent the expanded compressed air from freezing, its pressure dew
1)
point must be at least 10 K lower than the medium temperature.
7
ASSEMBLY
7.1 Safety instructions
DANGER!
Risk of injury from high pressure in the system!
▶ Turn off the pressure and vent the lines before loosening lines or
valves.
Risk of injury due to electrical shock!
▶ Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation!
▶ Observe applicable accident prevention and safety regulations for
electrical equipment!
WARNING!
Risk of injury from greatly accelerated device parts and uncon-
nected whiplashing compressed air hoses!
▶ Before pressurizing the valve, check that all screw connections and
screw joints are tight and secure.
Risk of injury from improper assembly!
▶ Assembly may only be carried out by authorized technicians and
with the appropriate tools!
english
Type 0470, 5470
5
1)
7