SAVE AND LOAD WELDING SETTINGS
The current settings are automatically saved and loaded at start up.
On top of the current settings, it is also possible to save and load 50 settings per each mode.
The memory recalls :
- Primary setting
- Secondary setting (MMA, CV)
- Secondary settings (MMA)
Save new settings :
- Maintain buttons
and
- Turn one of the two knobs
- The display indicates a memory set (01 to 50) while blinking.
- Turn the knob to select the memory set in which the desired settings will be saved. Validate by pressing the button
- The settings are saved / the menu exit is instantaneous.
Load existing settings :
- Maintain the buttons
and
- Turn one of the two knobs to display
- The display indicates a memory set (01 to 50) while blinking.
- Turn one of the two knobs to select the memory set containing the desired settings to load. Validate by pressing the button
The settings are loaded / the menu exit is instantaneous.

REMOTE CONTROL

CONNECTIONS AND RECOMMENDATIONS
The remote control works in all modes (except in semi-auto mode with a workshop wire feeder where all controls are on the wire feeder).
The remote control acts on the primary settings of the current process (MMA and TIG, voltage and gouging).
Connections :
1- Plug the remote control on the machine's front.
2- The machine will detect the remote control automatically and open a selection menu:
Foot pedal selection.
Remote control with potentiometer selection.
The remote ontrol type selection is done with the two knobs, the validation is done with the button
The LED (FIG-2, n°14) switches on.
It is possible to activate / deactivate the remote control without having to physically unplug the remote control. Press the button
seconds, the LED (FIG-2, n°14) indicates the state of the remote control (LED on = remote control on).
Operations :
• Manual remote control (GYS product ref. 045675).
The manual remote control can adjust :
- the current from 50% to 100% of the set intensity using the main knob. The displayed current setpoint matches the potentiometer position. The
displayed current setpoint becomes a 100% of the settings when the main knob is turned towards the machine's keypad.
- from minimum to the maximum of the voltage range (then the main knob has no effect). The voltage display shows the remote control variation.
• Foot pedal (option ref. 045682) :
The pedal control can adjust :
- the current from 50% to 100% of the set intensity using the main knob. The displayed current setpoint corresponds to a 100% of the value.
Connectors
Beyond the manual remote control and the pedal, it is possible to create you own connectors using the optional male socket (ref. 045699). For the
cabling layout, please see the diagram below utiliser a 10 kΩ potentiometer).
ref. 045699
EXAGON 400 CC/CV
during 3 seconds.
. Validate by pressing the button
during 3 seconds.
. Validate by pressing the button
G
F
A
F
E
D
C
External view
appears, release the buttons.
.
appears, release the buttons.
.
D
C
B
A
Electric diagram according to the remote control type.
.
.
.