  • DEUTSCH, seite 199
Inverter power
supply
Inverter output
Mechanical
specifications
Installation
Control and
operating
hydraulic
specifications
Sensors
Functions and
safety devices
Technical specifications
Voltage [VAC]
(Tol +10/-20%)
Phases
Frequency [Hz]
Current (380V- 480V) [A]
Leakage current to earth
[ma]
Voltage [VAC]
Phases
Frequency [Hz]
Maximum current [A rms]
Minimum current [A rms]
Max. power output [kW]
Mechanical power P2
Unit weight [kg]
(excluding packaging)
Package weight [kg]
Maximum dimensions
[mm](WxHxD)
Work position
IP protection rating
Max. ambient temperature
[°C]
Max. section of lead
accepted by input and
output terminals [mm²]
Min. diameter of cable
accepted by input and
output cable glands [mm]
Max. diameter of cable
accepted by input and
output cable glands [mm]
Pressure regulation range
[bar]
Options
Type of pressure sensors
Pressure sensor full scale
[bar]
Type of flow sensor
supported
Connectivity
Safety devices
ENGLISH
AD 5.5 AC
380-480
3
50/60
20,5-16,5
<3
0 - V alim.
3
0-200
15,0
2
8,2
7,5 CV / 5,5 kW
1 – 95% full scale without press.
Ratiometric (0-5V) / 4:20 mA
Serial interface
Multi inverter connection
Dry running
Current sensitivity on output phases
Temperature overload on internal electronics
Abnormal power supply voltages
Direct shorting between output phases
Fault on pressure sensor
73
AD 4.0 AC
AD 3.0 AC
380-480
3
50/60
16-12,0
<3
0 - V alim.
3
0-200
11,0
2
6,0
5,5 CV / 4 kW
11,2
14.0
251x370x180
Any
20
50
4
11
17
Flow sensor
16 / 25 / 40
5 pulses [Vpp]
380-480
3
50/60
12,5-10,0
<3
0 - V alim.
3
0-200
9,0
2
4,5
4 CV / 3 kW

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis