Herunterladen Inhalt Inhalt Diese Seite drucken

Harvia PP70 Gebrauchs- Und Montageanleitung Seite 45

Vorschau ausblenden Andere Handbücher für PP70:
Inhaltsverzeichnis

Werbung

Technical data
Dimensions
Connections
Sauna room volumes and
dimensions
Ambient conditions
Water quality
Type
Power kW
Fuse (400 V 3N~) A
Fuse (230 V 1N~) A
Protection class
Weight kg
Stone capacity kg
Stones
Temperature range for separate
safety sensor °C
Height
Width
Depth
Safety distance
Safety distance, top
Safety distance, bottom
Supply cord (400V 3N~) mm²
Supply cord (230 V 1N~) mm²
min Room volume m³ (structures
taken in account)
max Room volume m³ (structures
taken in account)
Saunaroom min. height
Product min. space requirements
mm
Storage temperature
Humus concentration
Iron concentration
Hardness
Chlorinated water
Seawater
PP70
PP90
6,8
9
3 x 10
3 x 16
35
40
IPX4
11,5
12,2
90 kg
Ø 5–10 cm, AC3000
-
-
1020 mm
310 mm
310 mm
100 mm
880 mm
20 mm
5 x 1,5
5 x 2,5
3 x 6
3 x 10
6
8
10
14
1900 mm
510 x 510 mm
0-50 °C
< 12 mg/l
< 0,2 mg/l
Mn: < 0,05 mg/l Ca: < 100 mg/l
Forbidden to use
Forbidden to use
PP70E
PP90E
6,8
9
3 x 10
3 x 16
35
40
11,0
11,7
125 °C
125 °C
5 x 1,5
5 x 2,5
3 x 6
3 x 10
6
8
10
14

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pp70ePp90Pp90e

Inhaltsverzeichnis