When several auxiliary setpoint functions are configured at the same time
on different inputs, the system will show Pi when at least one function is
activated. For simultaneous activations, the pressure achieved will be the
lowest of those with the active input. The alarm is removed when no input
is activated.
auxiliary setpoint
Behaviour of the
Value of
Input configu-
Parameter
ration
Ix
Active with high
signal on input
3
(NO)
Active with low
4
signal on input
(NC)
Table 16: Auxiliary setpoint
7.6.15.4 - Setting system disabling and fault reset
The signal that enables the system can be supplied to any input (for the
electrical connections refer to the control unit manual). The system disa-
bling function is obtained by setting the parameter Ix, relating to the input
to which the signal to be used to disable the system is connected, on one
of the values shown in Table 18.
When the function is active, the system shuts down completely and the F3
symbol appears on the main page.
When several system disabling functions are configured at the same time
on different inputs, the system will indicate F3 when at least one function is
activated and will remove the alarm when none is activated.
For the system to work with the disable function, the input must be active
93
function depending on Ix and on the
input
Input status
Operation
i-th auxiliary set-
Absent
point not active
i-th auxiliary set-
Present
point active
i-th auxiliary set-
Absent
point active
i-th auxiliary set-
Present
point not active
for at least 1 sec.
When the system is disabled, for the function to be deactivated (re-en-
abling the system), the input must not be active for at least 1 sec. The
behaviour of the function is summed up in Table 17.
When several disable functions are configured at the same time on differ-
ent inputs, the system will show F3 when at least one function is activated.
The alarm is removed when no input is activated.
This function also allows the resetting of any faults present, see table 18.
Behaviour of the system disabling and fault reset function depending on Ix
Shown on
display
Value of
Input configur-
Parameter
None
Ix
Active with high
Px
signal on input
5
Px
Active with low
None
6
signal on input
Active with high
signal on input
7
Active with low
8
signal on input
Active with high
signal on input
9
and on the input
Input status
Operation
ation
Absent
Motor enabled
(NO)
Motor disabled
Present
Absent
Motor disabled
Motor enabled
(NC)
Present
Absent
Motor enabled
Motor disabled +
(NO)
Present
fault reset
Motor disabled +
Absent
fault reset
(NC)
Motor enabled
Present
Absent
Motor enabled
(NO)
Present
Fault reset
Table 17: Disabling system restore and fault
Shown on
display
None
F3
F3
None
None
F3
F3
None
None
None