Herunterladen Inhalt Inhalt Diese Seite drucken

Menu Trigger; Menu Trigger Type - IFM Electronic EC2036 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Menu Trigger

F1 Trigger: AUTO
F2 COBl-IDs:
181,194,201,701
F1 Trigger: AUTO
F2 COB-IDs

Menu Trigger Type

F1 Auto
F2 Pre-trigger
F3 Mid-trigger
F4 Post-trigger
F1 Auto
F2 Pre-Trigger
F3 Mid-Trigger
F4 Post-Trigger
Seite/Page 54
Selection of the trigger type (=> menu "Trigger type").
Input of maximum four CAN COB IDs whose messages release triggering or
"FFF" for all IDs (3 digits, hexadecimal, 11 bits).
Triggering is released by no message. The cyclical writing of current
messages into the buffer starts by pressing "*Start" in the menu "Trace" and
stops by pressing "*Stop" in the menu "Trace".
Current messages are continuously and cyclically written into the buffer by
pressing "*Start" in the menu "Trace". When the trigger condition is met or by
pressing "*Stop" in the menu "Trace" the reception stops.
Current messages are continuously and cyclically written into the buffer by
pressing "*Start" in the menu "Trace". When the trigger condition is met
writing new messages into the buffer continues until half the buffer is
overwritten or by pressing "*Stop" in the menu "Trace".
Writing current messages into the buffer only starts when the trigger
condition is met and "*Start" in the menu "Trace" has been pressed. Writing
into the buffer continues until the whole buffer is full or by pressing "*Stop" in
the menu "Trace".