Menu Trigger Type
F1 Auto
F2 Pre-trigger
F3 Mid-trigger
F4 Post-trigger
F1 Auto
F2 Pre-Trigger
F3 Mid-Trigger
F4 Post-Trigger
Menu Trigger Message
F1 NMT,GUAR,EMCY
F2 SDO-Mess.
F3 PDO-Mess.
F4 All Types
F1 NMT,GUAR,EMCY
Seite/Page 42
Triggering is released by no message. The cyclical writing of current
messages into the buffer starts by pressing "*Start" in the menu "Trace" and
stops by pressing "*Stop" in the menu "Trace".
Current messages are continuously and cyclically written into the buffer by
pressing "*Start" in the menu "Trace". When the trigger condition is met or by
pressing "*Stop" in the menu "Trace", the reception stops.
Current messages are continuously and cyclically written into the buffer by
pressing "*Start" in the menu "Trace". When the trigger condition is met,
writing new messages into the buffer continues until half the buffer is
overwritten or by pressing "*Stop" in the menu "Trace".
Writing current messages into the buffer only starts when the trigger
condition is met and "*Start" in the menu "Trace" has been pressed. Writing
into the buffer continues until the whole buffer is full or by pressing "*Stop" in
the menu "Trace".
Selection of the type of service message which releases triggering
F1 NMT-Mess.
F2 GUARD-Mess.
F3 EMERGCY-Mess.
F1 NMT-Mess.:
F2 GUARD-Mess.:
F3 EMERGCY-Mess.:
All NMT messages release triggering.
All Guard messages release triggering.
All Emergency messages release triggering.