3 INSTALLATION

Make sure that the supply voltage matches the voltage in-
dicated on the specifications plate of the welding machine.
When mounting a plug, make sure it has an adequate ca-
pacity, and that the yellow/green conductor of the power
supply cable is connected to the earth pin.
The capacity of the overload cutout switch or fuses installed
in series with the power supply must be equivalent to the
absorbed current I1 of the machine.
3.1 ASSEMBLY
Only skilled personnel should install the machine. All con-
nections must be carried out according to current regula-
W
X
Y
A
Z
D
E
AA
F
G
P
M
O
N
H
I
tions, and in full observance of safety laws (CEI 26-36 and
IEC/EN 60974-9)

3.2 DESCRIPTION OF THE EQUIPMENT

A Control panel.
B Central adapter.
This is where the welding torch is to be connected.
C Socket.
Socket to which you should connect the electrode
holder in MMA welding or the TIG torch power
connector.
D Fitting.
This is where the gas hose from the TIG welding torch
is to be connected.