Adding fuel
Never add fuel when the machine is on. After use let the machine cool off tor at least 15 minutes before adding fuel.
Always use fuel that fulfils the following specifications: unleaded petrol, octane content at least 85, mixed with oil
(mix ratio oil:petrol1 : 50).
Never smoke near the machine or the fuel. Never add fuel in the
vicinity of sparks, flames or open fire.
Remove the lid (11) from the filler opening
Pour the fuel carefully in the filler opening.
Never fill the tank further than to the top of the fuel filter.
Place the lid back on the filler opening.
Starting the motor
Be sure that NO load is connected.
Turn the fuel cock (fig B/3) to the position „ON".
Slide the choke (fig B/2) all the way to the left.
Put the on/ off switch (fig B/1) in the position „ON".
Pull gently on the start cord (fig B/4) until you feel resistance.
Pull the start cord forcefully. Repeat this until the motor is running.
Slide the choke slowly all the way back to the right.
Use ot the generator
Start the motor as described above and wait until the indicator lamp (fig B/5) goes on.
To connect a net-supplied machine or equipment, put the mains plug in the alternating current output (fig B/9).
In case of short circuit or overload of an output an electronic safety feature switches this off. The indicator lamp will remain on.
To switch the alternating current output back on, press the reset button (fig B/7).
Switching off
Be sure that NO load is connected.
Put the on/ off switch (fig B/1) in the position „OFF".
Turn the fuel cock (fig C/3) to the position „OFF".