MA502-S
Appendix: Parameter list
11 Appendix: Parameter list
(in English language, parameter LANGUAGE: = "eng")
11.1 Linear path measurement
SHOW = "lin"
Display
Designation / value range
RESOL:
Resolution: 10, 1, 0.1, 0.01 (mm), 1i, 0.1i,
0.01i, 0.001i (inch), free
FAC:
Calculating factor: (only resolution 'free')
0.00001 ... 9.99999
REF:
Reference value: -999999 ... 999999
OFF:
Offset value: -999999 ... 999999
DEC:
Decimal point: 0., 0.0, 0.00, 0.000, 0.0000
DIR:
Counting direction: up, down
TRS:
Type of reference switch: n.open, n.closed
STO:
Current value memory: on, off
RESET:
Reset enable: on, off, del.1s, del.3s
ABS/REL:
Incremental measurement enable: on, off
REF.EN:
Reference value input enable: on, off
OFF.EN:
Offset input enable: on, off
MM/IN.EN:
mm/inch changeover enable: (only for met-
rical resolution) on, off
P-KEY:
Delay of
30s
LANGUAGE: Language: ger, eng
BAUD:
Interface's baud rate: 2400, 4800, 9600,
19200, SIKON.3, ACTUAT
UpL:
Upper limiting value: (only if option swit-
ched outputs 'ACTUAT') -999999...999999
LoL:
Lower limiting value: (only if option swit-
ched outputs 'ACTUAT') -999999...999999
ADR:
Adress setting: (only if option SIKONETZ3
'SIKON.3') 1-31
UNITS:
Unit of measure: --, mm, cm, m, km, in, °
DIS.ANGLE: -5 ... +4
MA502-S · Date 13.03.2014 · Art. No. 81781 · Mod. status 422/13
key in seconds: 3s, 5s, 10s, 20s,
Your
Your
programming I
programming II
English
41