Herunterladen Inhalt Inhalt Diese Seite drucken

General Information About The Application Technique; Spraying Technique; Shutting Down And Cleaning; Cleaning The Mortar Hose - WAGNER Plast Coat 830 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für Plast Coat 830:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Plast Coat 830
7
GENERAL INFORMATION ABOUT
THE APPLICATION TECHNIQUE
7.1

SPRAYING TECHNIQUE

be uneven.
Examples:
Fine texture
Rough texture
Higher convey capacity –> larger amount of atomizing air
Test the desired texture on a test surface.
lapping of the next coat.
the surface to be coated, the paint mist is minimized.
Note:
Grains and pigments with a sharp edge result in a high rate of
wear of the pump, mortar hose, material tap and tip.
When using the mortar hose while working
hose along the outside of the scaffolding.
8

SHUTTING DOWN AND CLEANING

Do not clean the motor and control unit of
the mortar spraying machine moistly. And
certainly do not spray down the unit with
high-pressure cleaners or high-pressure
steam cleaners. Danger of short-circuits
caused by water ingressing.
8.1

CLEANING THE MORTAR HOSE

Important: Do not let the mortar spraying
machine run dry. Switch the device off im-
mediately if no more material comes out of
the tip or if the spray line becomes irregu-
lar. Possible reasons for the problem and
how to correct it can be found in the chap-
ter called „Eliminating faults".
–> large amount of atomizing air
–> small amount of atomizing air

GENERAL INFORMATION ABOUT THE APPLICATION TECHNIQUE

Important: Do not let the mortar spraying machine run
dry. During the cleaning process, ensure that there is al-
ways enough water in the container.
using pneumatic lance, set selector switch to "F".
exiting the hose is just a thin liquid.
using pneumatic lance, set selector switch to "A".
The mortar hose must be pressureless.
If necessary, set the selector switch briefly
to "R" (reverse).
Watch the manometer ––> 0 bar.
Wear safety goggles.
-
hose
-
cleaning process 3 – 4 times.
The mortar hose must be pressureless.
If necessary, set the selector switch briefly
to "R" (reverse).
Watch the manometer ––> 0 bar.
Wear safety goggles.
A further cleaning option is to use the clean-
This cleaning adapter can be connected to a
pling.
Insert cleaning ball into the mortar hose. Cou-
ple the mortar hose to the cleaning adapter
and rinse through with water.
8.2
CLEANING THE DEVICE AND REPLACING THE
STATOR
To do so, pump graphite pump sliding means or water mixed
with dishwashing liquid through the pump.
GB
-
43

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Plast coat 430

Inhaltsverzeichnis