MSI 400
Main module of the modular
safety controller MSI 400
Original operating instructions
About this document
1.1
Documentation for the system MSI 400
This installation manual describes the installation of the
controller module MSI 4xx of the configurable safety control
MSI 400.
The installation of the MSI 400 expansion modules
MSI-EM-I8-xx / MSI-EM-IO84-xx / MSI-EM-IO84NP-xx, the
relay-modules MSI-FB-CANOPEN / MSI-FB-PROFIBUS /
MSI-FB-ETHERCAT is described in separate installation
manuals.
Installation, configuration and operation of the configurable
safety control MSI 400 is described in the system manuals
„MSI 400 Hardware" and „MSI 400 software (MSI.designer)".
Document
Title
Manual
MSI 400 Hardware
Manual
MSI 400 software (MSI.designer)
MSI 400 Gateways
Above all, technical knowledge in the installation of protection
on machinery is necessary, which is not part of this manual.
1.2
Function of this document
This installation manual is intended for the technical staff of
the machine builder or machine operator enabling safe
installation of the configurable safety control MSI 400.
This installation manual is not a manual for the operation of
the machine. Information about that is part of the manual of
the machine.
On safety
This chapter is for your safety and the safety of the machine
operator. Please read this chapter carefully before starting
the installation.
2.1
Qualified persons
The configurable safety controller MSI 400 has to be installed
by qualified persons.
Qualified is, who ...
 has an adequate technical education and
 is instructed by the machine builder in the operation of the
machine and the significant safety guidelines and
 has access to the manuals of MSI 400 and has read and
understood these manuals and
 has access to the manuals of the protection equipment of
the machine being connected to the configurable safety
controller and has read and understood these manuals.
2.2
Application area of the system
MSI 400 is a configurable safety controller for safety
applications and is applicable
 according to EN 61508 up to SIL 3
 according to EN 62061 up to SIL CL 3
 according to EN ISO 13849-1:2015 up to Performance
Level (PL) e
 according to EN ISO 13849-1 up to category 4
 according to 50156-1 up to SNS 3
 according to EN 61511
The actual level of safety depends on the wiring, the
parameterization, the switching elements and its installation
on the machinery.
The configurable safety control MSI 400 is monitoring tactile
switching safety elements (e.g. E-Stop buttons, safety
switches, safety interlocks, lightcurtains, laser scanner) and
processing their signals. With its safe switching outputs the
configurable safety control can switch off actuators (e.g.
contactors, magnets, valves) of machines or plants.
Leuze electronic GmbH + Co. KG
info@leuze.de • www.leuze.com
2.3
Intended operation
The configurable safety control MSI 400 is operating only
within its specified operating limits (voltage, temperature etc.,
see technical data and chapter „Application area of the
system"). The system has to be operated only by experts and
on the machine on which the system is mounted according to
the MSI 400-operation manuals by qualified staff.
In the case of any other use or modifications of the device -
including those made for the purpose of mounting and
installation - all warranty claims against the manufacturer
become void.
2.4
General safety advices and safety measures
WARNING
 With installation and operation of the configurable safety
controller MSI 400 you have to respect the local standards
and directive in your country.
 For installation and use of the configurable safety controller
MSI 400 and for service and maintenance of the system
national laws and directives are binding, specially
– the EMC-Directive 2014/30/EU
– the Machine Directive 2006/42/EG
– the Safety Requirements of the Work Directive
2009/104/EC
– the Low-voltage-directive 2014/35/EU
– the Lift directive 2014/33/EU
– the Health and safety at Work Act / Safety guidelines.
 Manufacturer and operator of the machine, using a
configurable safety controller MSI 400, have to respect all
legally binding safety regulations at their own responsibility
in coordination with the responsible authorities.
 All advices and tests described in the manuals must be
respected necessarily.
 All tests during the installation have to be made by trained
staff respectively by specially instructed personal and the
tests have to be documented in a comprehensible way.
 The external voltage supply of the modules has to bridge
gaps of voltage of 20 ms according to EN 60204.
Appropriate power supplies are available from Wieland
Electric.
 The modules of the system MSI 400 comply with class A,
group 1 according to EN 55011.
– The group 1 covers all ISM-devices, where HF-energy is
produced and/or used for the inner function of the device.
WARNING
2.5
Disposal
The disposal of defective modules has to be done in
accordance with the local regulations for waste disposal (e.g.
European code for waste 16 02 14).
In der Braike 1 D-73277 Owen
Tel. +49 (0) 7021 573-0
Pay attention to the safety advices and
protection measures!
Notice the following hints in order to guarantee
the intended operation of the configurable
safety controller MSI 400.
The system MSI 400 covers the requirements
for class A (Industrial Use) according to
EN 55011!
Therefore MSI 400-System is designed only for
the use in the industrial environment and it is
not designed for the use in the private
environment.
We reserve the right to make changes
02/2018 – 50134613-01 – 7/32