BTL7-S5 _ _ (B)-M _ _ _ _ -A/B/CD/Y/Z(8)-NEX-S32/KA _ _
Micropulse Transducer - Rod Style
7
Configuration using the Micropulse Configuration Tool (only for BTL7-S510(B)-...)
7.1
Micropulse Configuration Tool
The BTL7-S510(B)-... transducer can be configured
quickly and simply on a PC using the Micropulse
Configuration Tool PC software.
The most important features include:
–
Online display of the current position of the magnet
–
Graphical support for setting the functions and curves
–
Display of information on the connected transducer
–
Selectable number formats and units for display
–
Resetting to factory settings is possible
–
Demo mode without having transducer connected
The PC software and associated manual can
be found in the Internet under
www.balluff.com.
7.2
Connecting the USB communication box
For BTL7-S510(B)-... transducers with connector, the
communication box must be looped in between the
transducer and controller. The communication box is
connected to the PC via a USB cable.
USB cable
Connection cable approx. 0.3 m
with connector (socket)
Fig. 7-1:
Connecting the communication box with a connector
For a BTL7-S510(B)-...-KA_ _ transducer, the
communication lines La, Lb and GND must be connected
to the USB communication box.
USB cable
Fig. 7-2:
Connecting the communication box with a cable
connection
When reading or writing data via the
Configuration Tool, the LED 2 flashes green.
18
english
Connection cable
approx. 0.3 m with
connector (plug)
Controller
8-pin
6-pin
Controller
8-pin
Connection cable
approx. 0.6 m with
luster terminal
7.3
Configuration options
Prerequisites
–
USB communication box connected to the transducer
and PC.
–
Software correctly installed.
–
Transducer connected to the power supply.
–
Magnet on transducer.
Output functions
Position: Position in the measuring range.
–
Speed: Speed of the magnet; the sign indicates the
–
direction of movement. A movement from the starting
point to end point is output with a positive sign; a
movement from the end point to the starting point is
output with a negative sign.
–
Speed (unsigned): Speed of the magnet, the direction
of movement cannot be read.
–
Differential position: Distance between two magnets.
Selection is only possible if two magnets have been
selected.
–
Speed difference: The speeds of two magnets are
subtracted to form a sum. Selection is only possible if
two magnets have been selected.
Freely configurable curve
–
The gradient of the characteristic curve can be set by
adjusting the resolution.
–
The limits can be adjusted to the measuring range.
–
The error value can be set.
Boundary conditions for several magnets
–
Two magnets can only be selected from a nominal
length ≥ 90 mm.
–
The distance between two magnets must be ≥ 65 mm.
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► The system must be taken out of operation before
configuration.
► Transducers may only be connected to the
communication box for configuration.
► The communication box must be removed after
configuration.
Ignition protection
"nA" and "tb"