en
�6 | �LS ��4� | Decommissioning
9.
Decommissioning
9.�
Temporary shutdown
In the event of lengthy periods of non-use:
¶
Disconnect the VLS 5140 from the mains.
¶
Lock the master switch.
9.2
Change of location
¶
If the VLS 5140 is passed on, all the documentation
included in the scope of delivery must be handed over
together with the unit.
¶
The VLS 5140 is only ever to be transported in the
original or equivalent packaging.
¶
Unplug the electrical connection.
¶
Heed the notes on initial commissioning.
9.�
Disposal and scrapping
9.�.�
Substances hazardous to water
!
Oils and greases as well as refuse containing oil and
grease (e.g. filters) represent a hazard to water.
1. Substances hazardous to water must not be allowed
to enter the sewage system.
2. Substances hazardous to water must be disposed of
in accordance with the applicable regulations.
9.�.2
�LS ��4� and accessories
1. Disconnect the VLS 5140 from the mains and detach
the power cord.
2. Dismantle the VLS 5140 and sort out and dispose
of the different materials in accordance with the
applicable regulations.
The �LS ��4� is subject to the European
directive 2��2/96/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
¶
Make use of the local return and collection
systems for disposal.
¶
Proper disposal of the VLS 5140 prevents
environmental pollution and possible
health hazards.
|
1 689 989 122
2012-09-13
10. Technical data
��.�
Ambient conditions
��.�.�
Use
Property
Temperature
Humidity
��.�.2
Storage and transportation
Property
Temperature
Humidity
��.2
Performance data
��.2.�
Lifting platform
Feature
Load-bearing capacity
Load distribution
Lifting height
Lifting time
Lowering time (when loaded)
��.�
Operating data
��.�.�
Electric current
Feature
Phases
Nominal voltage
Frequency
Fuse protection
Rated current
Rated power
Control voltage
Duty cycle
Degree of protection
Protection class
�alue/Range
-25 °C – 45 °C
-13 °F – 113 °F
20 % - 80 %
�alue/Range
-25 °C – 60 °C
-13 °F – 140 °F
30 % – 60 %
�alue/Range
4000 kg
2 : 1
1850 mm
35 s
35 s
�alue/Range
3P / N / PE
400 V AC
50 Hz
3 x 20 A
9.5 A
5.5 kW
24 V AC
S3 -50 %
IP 54
/ II
Robert Bosch GmbH