Mounting
WARNING
WARNING
8012183/YTC9/2016-04-12
Subject to change without notice
Mounting
The IN4000 Direct safety switch is only allowed to be
fitted by authorized specialist personnel.
Select the mounting location and the mounting position
for the safety switch such that
• it is difficult for operators to access the safety switch
when the protective device is open,
• it is possible to inspect and replace the safety
switch.
Bypassing the inductive safety switch by simple
means or unintentional actuation must be prevented
by appropriate installation features as per
EN ISO 14 119.