Herunterladen Inhalt Inhalt Diese Seite drucken

Access To The Operating Menu Via The Local Display - Endress+Hauser Nivotester FTR525 Anleitung

Vorschau ausblenden Andere Handbücher für Nivotester FTR525:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating options
6.3

Access to the operating menu via the local display

6.3.1
Operational display (initialisation)
1
-8.8.8.8.8
1M
5
2M
4
24 Initialisation display
1
Measured value or function/function group number display
2
Operation lock display
3
Minimum/maximum value display
4
Dot matrix display for Tag, bar graph, unit, switch point, etc.
5
Measuring channel display: 1M = level limit detection; 2M = bulk flow detection
6.3.2
Measured value display
2M
Grenzstand 1
5
4
25 Measured value display
1
Numerical measured value display
2
Measured value unit display
3
Relay/SSR 1 switch points display
4
Relay/SSR 2 switch points display
5
Measured value bar graph display
Depending on the setting, the measured value display will display either the measured value
of the first measuring channel (1M), the measured value of the second measuring channel
(2M) or an alternating display of the measured values of both measuring channels (1M/2M).
Example: Bar graph of 1M/2M alternating
1M
Grenzstand 1
Overview of all available display options → 69
56
5 8
%
8 2
5 seconds
%
%
2
Max
3
Min
1
%
2
3
2M
Grenzstand 1
Nivotester FTR525
5 8
%
%
Endress+Hauser