Installation Instruction
Transmitter electronics FHX50
Levelflex FMP5x, Micropilot FMR5x, Promass 200, Prowirl 200, Promag 200, Prosonic Flow 200
EA01064F/00/A2/03.15
71279010
Instruction is valid for the following spare part set:
Order number
Original spare part set
71197334
Transmitter electronics FHX50
We recommend that the Installation Instructions be kept with the packaging at all times.
Designated use
The spare part set and Installation Instruction are used to replace a faulty unit with a functioning unit of the same type.
Use genuine parts from Endress+Hauser only.
Only original spare part sets, intended by Endress+Hauser for the measuring device, shall be used.
The verification has to be done via Online Support, this procedure is explained below.
For some devices there is an overview of the correct spare part set inside the connection compartment cover.
If the spare part is listed there, the verification is not required.
www.endress.com/support
1.
2.
Device specific information
3.
Ser. No.:12345
4.
=
?
5.
Usage
Feature: Display, Operation
Option
Levelflex FMP5x,
Micropilot FMR5x
Promass 200
L - Prepared for display FHX50 + M12 connection
Prowirl 200
M - Prepared for display FHX50 + custom connection
Promag 200
Prosonic Flow 200
www.endress.com/support
Choose device specific information.
Enter the serial number (Ser. No.), search for product data and click on
"spare parts".
Display of all suitable spare parts.
Check the order number of the spare part.
Does the order number of spare part correspond to the order number in
the spare part list?
YES, the spare part can be used.
NO, the spare part may not be used.
71279010