Herunterladen Inhalt Inhalt Diese Seite drucken

Hot Surfaces - Siemens SITRANS F Kompaktbetriebsanleitung

Ultraschall-durchflussmessgeräte
Vorschau ausblenden Andere Handbücher für SITRANS F:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29
WARNING
Hazardous contact voltage
Risk of injury through hazardous contact voltage when the device is open or not completely closed.
The degree of protection specified on the nameplate or in Technical data (Page 21) is no longer guaranteed if the device is
open or not properly closed.
Make sure that the device is securely closed.
5.1.4
Risk of explosion when medium above 100 °C flows through the process flange
WARNING
Risk of explosion when medium above 100 °C flows through the process flange
Explosion protection is no longer guaranteed and the approval is nullified.
It is prohibited for medium above 100 °C to continually flow through the process
flange.
WARNING
Loss of explosion protection
Risk of explosion in hazardous areas if the device is open or not properly closed.
Close the device as described in Connecting (Page 10).
5.1.5

Hot surfaces

WARNING
Hot surfaces
Risk of burns resulting from hot surfaces.
Take corresponding protective measures, for example by wearing protective gloves.
5.2
Local display
The device is commissioned/operated with the touch keypad on the local display.
The elements are actuated by touching the glass panel on the appropriate key. Pressing harder will not activate the key, but
using a thumb instead of a finger tip will help. The text display above the operating elements gives a menu-guided operation
of the individual device function/parameters. Successful operation of the key is confirmed by a small green LED at the right
of the display.
Full graphical display
LED (for indication of key operation)
Touch keypad
Figure 5-1
Local display
SITRANS FS230
A5E38755607-AA, 02/2017
19

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sitrans fs230

Inhaltsverzeichnis