Continuous ventilation after cutting off the hob:
• This is not a failure, the fan continuous to protect the
electronic device.
• The fan cooling stops automatically.
The automatic cooking system doesn't start-up:
• The cooking zone is still hot [ H ].
• The highest Booster level is set [ 9 ].
The control panel displays [ U ]:
• Refer to the chapter "Keep warm".
The control panel displays [ II ]:
• Refer to the chapter "Stop&Go"
The control panel displays [
• An object or liquid covers the control keys. The
symbol disappear as soon as the key is released or
cleaned.
The control panel displays [ E2 ] :
• The hob is overheated, let it cool and then turn it on
again.
The control panel displays [ E8 ] :
• The air inlet of the ventilator is obstructed, release it.
The control panel displays [ U400 ] :
• The hob is not connected to the network. Check the
connection and reconnect the hob.
The control panel displays [ Er47 ] :
• The hob is not connected to the network. Check the
connection and reconnect the hob.
If one of the symbols above persists, contact the SAV.

7.2 Messages at the extraction

Four flashing white LEDs:
• The suction tower has not correctly been placed in
the opening. Correctly position the suction tower or
clean the magnets at the bottom of the suction to-
wer and remove any grease.
The cooker hood does not extract well. What can be
the cause of this problem?
• Check the fat filter. Follow the cleaning indication.
Clean the filter every two weeks on average to en-
sure proper passing of the fumes.
• Check the air supply in the house. As soon as the
cooker hood is switched on, make sure that air is
supplied by opening the grates in the windows or by
opening a window.
• Check the duct for blockages or constrictions pre-
venting proper extraction of the air.

7.3 Technical problem

In case of technical problems please contact Novy
Service Department:
• For Belgium: Tel.: 056/36.51.02
• For France: Tel.: 03.20.94.06.62
• For Germany: Tel.: 0511.54.20.771
For all other countries: your local installor or Novy Bel-
gium: +32 (0)56/36.51.02
] or [ Er03 ] :
Please supply us with the model number of your hood.
The model number can be found on the en-
graved plaque behind the filter.
You can make a note of the number here:
.................................
EN 44