Resetting the data to the factory preset levels
There are three options for resetting the adjustment data to the
factory preset levels.
GEOM RESET: Resets ZOOM, H/V SIZE and H/V CENT
currently in use.
COLOR RESET: Resets CONTRAST, PHASE and CHROMA
currently in use.
ALL RESET:
Resets all user adjustment items to the factory
preset data and clears the memory contents.
The operation procedures are the same for the three options.
1
Press the MENU button.
The MENU 1 screen appears.
MENU
2
Press the CENT ◊/√ button to move the cursor (z) to
GEOM RESET, COLOR RESET or ALL RESET, and press the
ENTER button.
ENTER
CENT
3
Press the CENT ◊/√ button to move the cursor to
EXECUTE, and press the ENTER button.
The adjustment data are reset to the factory preset levels.
To cancel resetting
Press the MENU button, or select CANCEL in step 3 above and
press the ENTER button.
MENU 1
zMEM LOAD
MEM SAVE
GEOM RESET
COLOR RESET
ALL RESET
INDEX NO.
LANGUAGE
USE:
ENTER NEXT:MENU
ALL RESET
zCANCEL
EXECUTE
USE:
ENTER CANCEL: MENU
Using the test pattern
S
TV
ON/OFF
PJ
OFF
COMMAND
DISPLAY
ON/OFF
MODE
MENU
ENTER
TEST PATTERN button
You can use the built-in test patterns to adjust the monitor or
prejector screen.
Press the TEST PATTERN button.
Each time you press TEST PATTERN, the following test
patterns appear in sequence.
Hatch m Box m Color bar m Gray scale m OFF (input signal) m
Hatch m ...
TEST
PATTERN
The selected test pattern name is displayed on the screen for
about 3 seconds.
To restore the normal screen
Press the TEST PATTERN button repeatedly until no test
pattern is displayed. Pressing the ON/OFF switch, INPUT
SELECT buttons or OUTPUT FORMAT button also restores
the normal screen.
Note
When the test pattern is displayed, only the ON/OFF switch,
and the INPUT SELECT, OUTPUT FORMAT, MENU and
CENT ◊/√ buttons will function.
SIGNAL FORMAT
IN
NTSC
PAL
31.5k
OUT
NTSC
PAL
31.5k
TEST
LINE
OUTPUT
FORMAT
PATTERN
DOUBLER
GEN-LOCK
CENT
Example: Hatch
HATCH
39