Herunterladen Inhalt Inhalt Diese Seite drucken

Example1: Ip-Alarmmodule + Recorder - Abus CASA10010 Bedienungsanleitung

Das ip-alarmmodul verfügt über 2 kanalgruppen
Vorschau ausblenden Andere Handbücher für CASA10010:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Switch to the programming menu 6 and press the „SET" button. Now you can set „output
group 1" and „output group 2". The return channel for the remote control must be set to
group 1. Press „Select" to choose between group 1 and group 2. Select group 1 and press „SET". If the
status LED blinks the output for remote control feedback is configured correctly.
To save the settings, quit the programming menu by pressing the "ESC/DEL" button twice.
The confirmation with the set button is also necessary if your settings were already set
before!
Now learn in the radio magnetic contact into the IP alarm module. Switch to
"programming menu 1" and press the "SET" button. Select channel 5 for the magnetic
contact by pressing the "Select"-button until the fifth LED flashes. Open the tamper switch from the
detector to learn in to choosen channel.
The IP alarm module peeps twice if the detector was learnd in successfully.
Quit and save the programming menu by pressing "ESC/DEL-Taste" twice to save the settings. Put the
housing back onto IP alarmmodule. The setup process of the radio detectors at the IP alarm module is
completed.

6. Example1: IP-alarmmodule + Recorder

Painting
27
English

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis