3 Installation and Commissioning
Only competent personnel trained, qualified, and approved by Parker domnick hunter should perform installation,
commissioning, service and repair procedures.
3.1 Recommended System Layout
Ref
Description
1
Compressor
2
Wet air receiver
3
Water separator
3.1.1 Buffer vessel selection
The buffer selection should be sized according to the flowrate of the generator.
Pdh part number
606200238
606201440
606201444
606201450
606201452
3.1.2 Pre-treatment dryer selection
The following pre-treatment dryers are supplied with filtration and a purge economy lead.
Model
Part Number (230v 50Hz) Part Number (115v 60Hz)
DAS2 / N2
616200542
DAS3 / N2
616200543
DAS4 / N2
616200544
DAS5 / N2
616200545
DAS6 / N2
616200546
DAS7 / N2
616200547
DME012 / N2
616200203
DME015 / N2
616200217
DME020 / N2
616200225
DME025 / N2
616200233
8
Ref
Description
4
Dryer pre-filtration
5
Pre-treatment dryer
6
Dust filter
Flowrate
3
m
/hr
0 - 3
3.1 - 7.5
7.6 - 12.3
12.4 - 24
24.1 - 34
616200532
616200533
616200534
616200535
616200536
616200537
616200204
616200218
616200226
616200234
Ref
Description
7
MIDIGAS generator
8
Buffer vessel
9
Pressure relief valve
cfm
0 - 1.8
1.8 - 4.4
4.5 - 7.2
7.3 - 14.1
14.2 - 20
3
Outlet Flow Rate m
/hr
o
Up to 30
C
Up to 45
6.3
5.3
10.3
8.3
12.6
10.6
16.5
13.6
18.9
15.9
25.2
22.2
38.6
33.1
51.3
44.0
67.4
57.7
85.2
73.0
Ref
Description
10
Dust filter
11
Ball valve
12
Drain valve
Vessel capacity
L
50
150
250
500
750
o
3
C
Purge Loss (m
/hr)
1.7
2.7
3.4
4.4
5.1
6.8
7.31
9.85
12.91
16.14