Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly; Sunshield Mounting; Assembling The Camera And Motorised Lenses; Cameras Features - Videotec ULISSE MAXI NETCAM Bedienungsanleitung

Full ip ptz einheit fuer netzwerk-kameras fuer die dynamische ueberwachung grosser aussenbereiche
Vorschau ausblenden Andere Handbücher für ULISSE MAXI NETCAM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 195

7 Assembly

Only network cameras with specific
technical characteristics can be installed (
7.2.1 Cameras features, page 14).

7.1 Sunshield mounting

Mount the sunshield to the housing with the 4 screws
and 4 washers couples provided.
Fig. 6
7.2 Assembling the camera and
motorised lenses
The correct operation of the equipment,
within the temperature range indicated, is
guaranteed only if you use camera and lens
with temperature limits equal to at least
-10°C and +60°C.
The customer has to take care of assembling the
camera and lenses.
14

7.2.1 Cameras features

The correct operation of the equipment,
within the temperature range indicated, is
guaranteed only if you use camera and lens
with temperature limits equal to at least
-10°C and +60°C.
The camera must be pre-configured in
order to acquire the IP address via DHCP.
The camera must be pre-configured in
order to interface with the NTP server via
DHCP. If NTP configuration via DHCP is not
possible, set the following static address of
the NTP server: 192.0.0.1.
Only network cameras can be installed in
the unit.
• Only cameras with a 100 baseTx type Ethernet
communication port can be mounted.
• Only cameras powered by a terminal can be
mounted. The Pan & Tilt cannot supply power
directly on the Ethernet cable (Power over
Ethernet).
• The power supply voltage of the camera must be
12Vdc.
• The maximum current absorbed by the camera
must be lower than the value indicated below:
800mA.
• The communication protocol must be ONVIF,
S profile, protocol. The camera must be pre-
configured in order to communicate via the ONVIF,
S profile, protocol.
• The camera must be operate properly between
-10°C (14°F) and +60°C (140°F).
MNVCUPTMAXIR_1625_EN