Herunterladen Inhalt Inhalt Diese Seite drucken

General; Scope Of Supply; Year Of Construction; Motor Types - lutz B70V Originalbetriebsanleitung

Exzenterschneckenpumpen
Vorschau ausblenden Andere Handbücher für B70V:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. General

Each Lutz eccentric screw drum pump in series B70V/B70V-SR
comprises an universal, three-phase or compressed air motor
and a pump tube.
The pumps are available with a variety of seals, drive shafts
and stator materials.
The flow rate and delivery head depend on the selected pump
size. This means that the most appropriate pump can be chosen
for each individual application.

1.1 Scope of supply

The motor and pump tube of series B70V 12.1 to 75.1 are
packed in two separate cartons unless specified otherwise
by the customer.
The packaging may also contain any accessories ordered.
It is therefore important to check that the consignment is
complete as ordered.

1.2 Year of construction

The year of construction of the appliance can be seen on the
field for the serial number. Here are attached to the serial
number the both last digits of the year of construction, e.g.
(-10 for the year 2010).

2. Motor types

The Lutz eccentric screw drum pump of series B70V/B70V-SR
is available in three different versions:
2.1 Drive units for type B70V-D, series 12.1 to 75.1
Three-phase drives
The pumps of series B70V are driven by three-phase motors.
The following three-phase motors are available: 0.37, 0.55,
0.75, 1.1 kW and 1.5 kW, 700 or 900 rpm, 230/400 V, 50 Hz,
type of protection IP 54. Other types of protection, voltages,
motor ratings and speeds are available on request.
Further information can be found in the operating instructions
for three-phase motors.
Three-phase drives with frequency converter
To optimally adjust the volume flow and desired pumping head
of an eccentric screw drum pump, you can choose between
the following three-phase motors with attached frequency
converter: 0.55, 0.75, 1.1 and 1.5 kW.
More information can be found in the operating instructions
for three-phase motors.
High leakage current
A radio interference filter in the frequency converter
causes additional leakage current through the earth
conductor.
The earth leakage current can be between 3.5 and
11 mA depending on the clocking frequency.
Compressed air drives
Compressed air motors of type 4 DA, 6 DA or 8 DA rated at 0.45,
1.0 or 1.7 kW for 6 bar and 900 rpm. Operating pressure max.
7 bar, recommended speed 200-900 rpm, air consumption 55,
80 or 130 Nm³/h, air connection thread 1/4" NPT or 1/2" NPT.
Further information can be found in the operating instructions
for compressed air motors.
2.2 Drive units for type B70V-SR, series 12.1 to 50.1
The following universal motors and compressed air motors are
available for this type:
- Universal motor MA II and MI 4
- Universal motor ME II - explosion proof
- Compressed air motors MD-1, MD-2 and MD-3
Further information can be found in the respective operating
instructions.

3. Pump tubes

The eccentric screw pump of series B70V/B70V-SR is available
in a number of different versions as regards its sealing, drive
shaft, pump material, stator geometry and stator material. The
pump is used to deliver viscous, pure, turbid, aggressive and
non aggressive liquids.
Some pump versions of series B70V are approved for pumping
flammable liquids in explosion hazard areas Zone 0. The ap-
proval comprises the explosion group II A and the temperature
classes T1 - T4.
The approved pump tubes are marked with:
The pump tubes may only be installed in an upright position.