Quick Start Guide
5. Transducer Installation
Transducer Identification
Model
Hi Precision
NEMA w/F-Conn
Pipe Material
Note: Check to make sure that the transducers are a matched set with the same serial numbers and marked with an "A" and
"B" (e.g., 19256A and 19256B).
*Note: Transducer Model names for Version 3 op systems are as follows: 1011H Hi Precision, 1011 Universal and 991
Universal.
Reflect and Direct Mounting Modes
Reflect and Direct mounting modes are supported for clamp-on transducers. The Flow Display Computer recommends
a mounting mode after analyzing your pipe and liquid data entries. Note: For Direct Mount procedures see Flow Display
Computer manual.
Mounting Supplies
Transducer Installation
Example for D1H size High Precision Transducer Installation
Press <Left Arrow> to return to main menu. Press the <Down Arrow> to select [Install
Xdcr].
Press the <Right Arrow> to [Transducer Model]. Press <Right Arrow> and scroll to [1011HP-
T1].* Press <ENT>.
To select Transducer Size, press <Right Arrow> and select [D1H]. Press <ENT>.
IMPORTANT: Record Number Index and Spacing Method.
Transducers can now be mounted.
Siemens
2 Channel
Scroll List and select desired Model
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Complete
Empty Pipe Set
Zero Flow Adjust
Install Xdcr
Note: After transducers are mounted scroll to [Install Completed] and select [Install].
The transducer part number located on the front face provides a detailed identification. For
example, the Part Number: 1011HNFS-D1HUT1-S2 means:
1 0 11 H NF S - D1H UT1 - S2
The following items will be needed to mount the transducers:
Flat blade screwdriver
Mounting Frames or Mounting Tracks
Tape, chalk and a ruler or measuring tape
Mounting Straps
Spacer Bar
Mounting Guide (for Direct Mount)
Ultrasonic coupling compound
Transducers (matched set)
[1]
ABC
1011HP-T1
D1H
Reflect
Nominal
26
Spacer Bar 1012BN
7.499
No
MTYmatic
Actual Zero
Agency Approved
Temperature
Size
Select based on type.
Select based on size.
After transducer is mounted
select "Install."
13