| Electrical connections
Mount according to the enclosed Vibration Damper Quick Guide.
3. Lift the unit in place
Warning
Beware of sharp edges during mounting and maintenance. Use protective gloves.
Consider the unit weight when mounting!
4. Connect the unit to the duct system. Make sure that all necessary accessories are used to create a functional ventila-
tion solution.
Warning
The installation of the unit and complete ventilation system must be performed by an authorized installer
and in accordance with local rules and regulations.
Note:
The unit may not be installed with the electrical connection box facing downward due to the fact that the
heat from the re-heater is rising in the unit!
6.4
Condensation drainage
In general no condensation drainage is needed for rotational heat exchangers at dry conditions. However, if a lot of hu-
mid air is present in the residence, a condensation drainage might be needed. Drainage connection is available as an ac-
cessory and can be ordered separately.
Note:
The drainage connection is plugged in the bottom of the unit at delivery. To use the drainage: elevate the
unit from the floor, remove the rubber seal and connect the water hose. Connect the water hose to the
sewer. The water can not be led straight to the sewer without a water trap.
7
Electrical connections
The SAVE VSR 300/500 is wired internally from factory.
The electrical connection box is on top of the unit behind a cover plate.