ENGLISH
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's
reference number stamped on the plug.
Supply of replacement fuse covers can be
obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 12A and approved to
BS 1362.
3. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Connect to potable cold water supply only.
Note: A plumbing permit and services of a licensed
plumber may be required in some areas.
* The connections to the mains water supply
must be made in accordance with the countries'
current requirements of the Water Supply or
Water Fittings Regulations.
* I c e m a k i n g w a t e r m u s t b e p o t a b l e w a t e r.
Where scaling can be caused by water quality,
installation of an external filter or softener
is recommended. Contact your local water
treatment professional or Hoshizaki service
agent.
* Water supply pressure should be minimum 0.05
MPa (0.5 bar) and maximum 0.8 MPa (8 bar).
If the pressure exceeds 0.8 MPa (8 bar), use a
proper pressure reducing valve. Do NOT throttle
back the supply tap.
* The icemaker drain is gravity flow, so ensure
drain hose has an adequate pitch or fall.
* Drain lines should not be
installed directly to the
sewer system. A vertical
air gap of a minimum of
5 cm should be between
the end of the drain hoses
from the icemaker and
storage bin and the floor
drain.
* Be sure to use the new hose-sets supplied with
the appliance. Do not reuse any old hose-sets.
5cm air gap
Floor
Drain
Fig. 10
6
1) Attach the angled end of flexible inlet hose
(accessory) to the G3/4 fitting on the rear of the
icemaker as indicated, ensuring rubber sealing
washer is correctly positioned. Hand tighten
sufficiently to provide leak free joint.
2) Attach the other end of inlet hose to the water
tap, noting washer is correctly positioned before
hand tightening as above. It is a wise precaution
to have a stop valve within easy reach.
3) Hand tighten grey flexible outlet hose (accessory)
onto the R3/4 fitting on the rear of the icemaker
as indicated, ensuring rubber washer is correctly
positioned to obtain a leak free joint. The hose
can be cut to length as necessary to suit position
of main drain.
Inlet Hose
Outlet Hose
Fig. 11
6. START-UP PROCEDURE
1) C h e c k t h a t t h e p o w e r s u p p l y c o r d i s
disconnected.
2) Move the operation switch on the operation
panel to the "ON" position.
3) Open the water supply tap.
4) Connect the power supply and energise.
5) The display will illuminate in the "ICE" mode.
Water Supply Inlet G3/4
Drain Outlet R3/4
Water Supply Tap
Inlet Hose