Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Technical Specifications - SEVERIN DG 2429 Gebrauchsanweisung

Dampfgarofen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
without using any cleaning agent.
Trouble-shooting
Problem
The display is dark
The interior lighting doesn't work
During the cooking process, water
or steam can be seen leaking through The door seals are damaged
the door
Code
Problem
E-1
Thermal safety device cuts out: 240°C
E-2
Temperature too low: 35°C after 3 mins. of cooking
E-3
Steam-heating plate over-heating protection: in excess of 240°C
E-4
Steam-heating plate: temperature lower than 40°C after 3 mins. of cooking
E-5
Steam-heating plate sensor malfunction
E-6
Steam-heating plate sensor short-circuit
E-7
Door sensor malfunction
E-8
Door sensor short-circuit
E-9
Signal malfunction after 60-70 seconds

Technical specifications

Outside dimensions:
Unit weight:
Operating voltage:
Total power consumption:
- Steaming:
- Baking:
Disposal
Do not dispose of old or defective appliances in domestic garbage; this should only
be done through public collection points.
Guarantee
This product is guaranteed against defects in materials and workmanship for a period of two
years from the date of purchase. Under this guarantee the manufacturer undertakes to
repair or replace any parts found to be defective, providing the product is returned to one of
our authorised service centres. This guarantee is only valid if the appliance has been used in
accordance with the instructions, and provided that it has not been modified, repaired or
interfered with by any unauthorised person, or damaged through misuse.
This guarantee naturally does not cover wear and tear, nor breakables such as glass and
ceramic items, bulbs etc. If the product fails to operate and needs to be returned, pack it
carefully, enclosing your name and address and the reason for return. If within the guarantee
period, please also provide the guarantee card and proof of purchase.
Possible cause
The appliance has not been properly
connected.
Lamp is defective; During steam cooking,
the interior lighting is not active
The door is not properly closed
454 mm (W) x 403 mm (D) x 293 mm (H)
ca. 12.5 kg
220-240V ~ 50 Hz
1650 W
1250 W
21
Solution
Check the connection and fuse.
Contact your Customer Service to
replace the bulb
Check the door seals. If damage is
found, contact your Customer Service
Solution
Let the appliance cool down
Contact your Customer Service
Let the appliance cool down
Contact your Customer Service
Contact your Customer Service
Check that the water container is
properly fitted and filled with water.