The memory for extreme values (icon „
of resetting until another change results.
The extreme values of the last 24 hours (regular display below the outdoor temperature/
humidity cannot be reset when the icon „
Other
• If the measuring range of the indoor/outdoor temperature is undercut, the measured value
or extreme value „LL.L" is displayed; „HH.H" is displayed when it is exceeded.
• If the measured range of the indoor/outdoor humidity is undercut, the display shows a
humidity value of 20% and a small arrow to the right of it „ ".
i) Alarm Function for Outdoor Temperature
The weather station offers the option of issuing an alarm signal when a specific outdoor
temperature is exceeded and/or undercut.
Switching Alarm Function On/Off
Push the button „ALERT" (B7) repeatedly to choose between the following function:
• Display „ ": Alarm when the upper threshold is exceeded
• Display „ ": Alarm when the upper threshold is undercut
• Display „ ": Both alarms active
• No display: Both alarms deactivated
Setting the alarm temperatures
• Hold down the „ALERT" button (B7) for three seconds until the sound signal is issued. The
display shows the upper threshold now (E.g. +50 °C) and the icon „ " flashes.
• Set the upper threshold with the button „+" (B4) or „-" (B5) (step width 1 °C).
Keeping the respective button down for some time will adjust quickly.
If you do not push any button for about 15 seconds, the weather station saves all
input and leaves the setting mode automatically.
• Briefly push the button „ALERT" (B7), the display shows the lower threshold (e.g. -20 °C) and
the icon „ " flashes.
• Set the lower threshold with the button „+" (B4) or „-" (B5).
• Briefly press the button „ALERT" (B7) again to leave setting mode.