Failures – causes - removal
(problem):
Engine does not start
(cause):
1.
No system voltage
2.
Blocked pump wheel
(measures):
1.
Check the voltage
2.
Inspect the pump wheel for foreign
objects
(problem):
Pump does not suck
(cause):
1.
Pump without water
2.
Water level too low
3.
Blocked pump wheel
(measures):
Let the air bubbles release (pic. D)
1.
2.
Switch the pump off, water level
must go up.
3.
Remove the obstruction
(problem):
Insufficient amount of water pumped
(cause):
1.
Dirty tube filter
2.
Water level quickly going down
3.
Maximum head of delivery exceeded
4.
Transport guide broken
(measures):
1.
Clean the tube filter
2.
Ensure sufficient inflow
3.
Check the transport path length
4.
Check the transport guide
(problem):
Thermal detector switching the pump
off
(cause):
1.
Dirty tube filter
2.
Water temperature too high
3.
Pump running continuously at
maximum pressure.
(measures):
1.
Clean the tube filter and let the
pump cool down
2.
Reduce the water temperature
3.
Make more breaks
Inspections and maintenance
Except for the below-described cases, the pump must be
delivered to the customer service department for any repairs.
Sand and other abrasive solids cause premature wear and
pump power reduction. Works on the pump electric
equipment can explicitly be executed by the customer service
department. Oilless bearings. Occasional filter support
cleaning is enough, no other maintenance is necessary.
Original spare parts must only be used in any case.
To ensure long service life of the pump seal, we
recommend rinsing the pump with clean water in regular
intervals.
Safety instructions for inspections and maintenance
It is always necessary to interrupt feeding (plug pulled out of
socket) and make sure the pump is not going to start before
any pump maintenance. Only a regularly maintained and
treated appliance can serve as a satisfactory aid. Insufficient
maintenance and care can lead to unforeseen accidents and
injuries.
Inspection and maintenance plan
Time interval
Description
Cleaning and rinsing
As needed
out
Service
Any technical questions? Complaint? Do you need spare
parts or operation manual?
Go to our website www.guede.com and the section Service
will help you quickly and without bureaucracy. Please, help us
to help you. In order to identify your device in case of
complaint, please indicate serial number, order number and
year of manufacture. All information is available on the
product label. To have all information always at hand, put
them down.
Serial number:
Order number:
Year of manufacture:
Phone:
+49 (0) 79 04 / 700-360
Fax:
+49 (0) 79 04 / 700-51999
E-Mail:
support@ts.guede.com
Important information for the customer
Please be sure to know that returning the product in or after
the warranty period must be made in the original packaging.
EU Declaration of Conformity
GB
We, Güde GmbH & Co. KG Birkichstraße 6, 74549 Wolpertshausen,
Germany, hereby declare the conception and construction of the
below-mentioned appliances correspond - at the type of construction
being launched - to appropriate basic safety and hygienic
requirements of EC Directives.
In case of any change to the appliance not discussed with us the
Declaration expires.
Marking of appliances: GTT 900 Order No.: 94138
Date/producer signature: 15.09.2008
Signed by: Mr Arnold, Managing Director
Appropriate EU Directives:
2006/95/EC
89/336/EEC
93/68/EEC
Harmonised standards used:
EN 60335-1:2002+A1+A11+A12
EN 60335-2-41:2003+A1
EN 50366:2003+A1
EN 55014-1:2000+A1+A2
EN 55014-2:1997+A1
EN 61000-3-2:2000+A2
EN 61000-3-3:1995+A1+A2
EN 61000-3-3:1995+A1+A2
Certification place:
TÜV Rheinland Product Safety GmbH, Am Grauen Stein,
D-51106 Köln
Reference No.:
14701485006
Any other
details