Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning The Hygienic Exhaust Filter; Spare Parts And Accessories; Before You Send In The Appliance - Dirt Devil CP-2 Bedienungsanleitung

Black label
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5 Maintenance

5.4 Cleaning the hygienic exhaust filter

13
14

5.5 Spare parts and accessories

ATTENTION:
Only use original spare parts from the scope of delivery or those that you
have purchased by reordering.
Ordering address: ZPage 48, "International Service"
Further information: Z www.dirtdevil.de
The adjacent accessory parts and spare parts can be reordered.

5.6 Before you send in the appliance

WARNING:
Danger of injury! Never use a defective appliance! Always switch off the
appliance and disconnect it from the mains before starting troubleshoot-
ing ZChapter 4.3, "Switching off".
Before contacting your authorised Royal dealer, Royal service partner or
appliance market or sending in the appliance, first follow the procedure in
the following table to check if you can solve the problem yourself.
NOTE:
If you were unable to solve the problem with the information in the above
table, contact Customer Service (ZPage 48, "International Service").
Problem
The appliance
The socket does not carry current.
will not start.
Test the vacuum cleaner at another socket which you
are sure carries current.
Power cord is damaged. Have the cord replaced by the
Royal Appliance Customer Service, address ZPage
48, "International Service".
The vacuum
The overheating protection has tripped (possibly due
cleaner stops
to blocked suction channels, filters, or similar).
suddenly.
Switch the appliance off and pull the plug out of the
socket. Remove the cause of overheating (e.g. by dis-
assembling telescopic tube and suction hose and re-
moving the obstacle and/or cleaning filters). Wait for
about 45 minutes. After the appliance has cooled off,
you may switch it on again.
A
A
Solution
It is best to check/clean the hygienic exhaust filter each time you clean
B
the dual motor protection filter, ZChapter 5.3, "Cleaning the dual motor
protection filter".
1. Switch off the appliance, ZChapter 4.3, "Switching off".
2. Slide the release catch of the exhaust filter cover to the right (Fig. 13/A)
and open the exhaust filter cover.
3. Remove the hygienic exhaust filter (Fig. 13/B).
4. Tap the dirt out of the hygienic exhaust filter over a dustbin.
5. Remove residual dust with a soft brush, e.g. the supplied furniture
brush.
6. If the hygienic exhaust filter is still dirty after this procedure, thoroughly
rinse it by hand in running water until all dirt is gone.
ATTENTION:
The filter is washable, but it may not be cleaned in dishwashers or
B
washing machines. Also, do not use detergents or brushes with hard
bristles to clean the filters. Let the filter dry for approx. 24 hours at room
temperature after washing it. Only put it back in place when it is
completely dry.
7. If the exhaust filter is damaged, deformed or too soiled, replace it
(ordering information ZChapter 5.5, "Spare parts and accessories").
8. Place the clean/new exhaust filter back into its receptacle (Fig. 14/A).
9. Fit the exhaust filter cover on the bottom first and then pivot it in
upwards into place (Fig. 14/B).
Item number
2838001
Dual motor protection filter consisting of:
1 foam plastic filter element and 1 filter holder
2838002
1 hygienic exhaust filter
M203-5
1 parquet brush
M209
1 turbo brush
M219
1 mini turbo brush
M232
1 long, flexible crevice nozzle
Problem
The cleaning re-
The bypass vent (Fig. 1/26) is open.
sults are unsat-
Close the bypass vent (Fig. 1/26).
isfactory in spite
The attached nozzle is unsuitable.
of the appliance
Change the nozzle, ZChapter 3.2, "Selecting the
working correct-
proper nozzle".
ly.
The position of the "carpet/hard floor" selector (Fig. 1/
2) is unsuitable. Set the "carpet/hard floor" selector
(Fig. 1/2) to the correct position for the type of floor,
ZChapter 4.2, "Vacuum cleaning", step 4.
The dust container is full.
Empty the dust container, ZChapter 5.1, "Emptying
the dust container".
The filters are dirty. Clean the respective filter
ZChapter 5.2, "Cleaning the dust container and cy-
clone unit" or ZChapter 5.4, "Cleaning the hygienic ex-
haust filter".
When vacuum-
The pressure in the vacuum cleaner became too low
ing with the long,
and caused the safety valve to trigger.
flexible crevice
Open the bypass vent until the valve no longer trig-
nozzle, there is
gers.
suddenly a high-
pitched whistling
and the suction
power drops
considerably.
Description
Solution
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis