EN
3. INSTRUCTIONS FOR INSTaLLaTION
3.1. Before Installation
Before installing the heater, study the instructions
for installation. Check the following points:
Is the output and type of the heater suitable for
•
the sauna room? The cubic volumes given in
table 2 should be followed.
Is the supply voltage suitable for the heater?
•
The location of the heater fulfils the minimum
•
requirements concerning safety distances given
in fig. 4 and table 2.
Note! Only one electrical heater may be installed in
the sauna room. The heater should be installed so
that the warning texts can also be read without dif-
ficulty after the installation.
Heater
Ofen
HL70
HL90
HL110
Table 2.
Installation details of the heater
Tabelle 2.
Montageinformationen zum Saunaofen
min. mm
30
Figure 4.
Safety distances (all dimensions in millimeters)
Abbildung 4. Sicherheitsmindestabstände (alle Abmessungen in Millimetern)
Figure 5.
Opening the cover of the service hatch
Abbildung 5. Öffnen der Serviceabdeckung
Output
Mitat
Leistung
Mått
Width/Depth/Height
Breite/Tiefe/Höhe
kW
mm
6,8
415/340/810
9,0
415/340/810
10,8
415/410/810
30
30
30
30
1
DE
3. MONTaGEaNLEITUNG
3.1. Vor der Montage
Lesen Sie die Montageanleitung, bevor Sie den Sau-
naofen installieren. Überprüfen Sie die folgenden
Punkte:
Ist der zu montierende Saunaofen in Leistung
•
und Typ passend für die Saunakabine? Die
Rauminhaltswerte in Tabelle 2 dürfen weder
übernoch unterschritten werden.
Ist die Netzspannung für den Saunaofen geeignet?
•
Der Montageort des Ofens er füllt die in Abb. 4
•
und Tabelle 2 angegebenen Sicherheitsmindest-
abstän de.
aCHTUNG! In einer Sauna darf nur ein Saunaofen
installiert werden. Der Saunaofen muß so installiert
werden, daß die Warnanweisungen nach der Mon-
tage leicht lesbar sind.
Weight/
Gewicht
kg
21
21
24
30
2
Stones
Sauna room
Steine
Saunakabine
Cubic vol.
Rauminhalt
2.3.!
max. kg
min. m³
max. m³
50
5
10
50
8
14
70
9
18
Height
Höhe
min. mm
1900
1900
1900
9