Menu Structure
NOTE
Heating request
A heating request is pending if the "Return set temperature" minus the
"Hysteresis return temperature" is higher than the current measured
"Return temperature".

8.3 History

The "History" menu can be used to query the runtimes of some
of the components in the heat pump heating system.
You can access the history menu by:
Pressing the button (MENU) for approx. 5 seconds
www.dimplex.de
Display of sensor and system values
Displays the humidity measured in the room in which room climate
control station 1 is installed. This value is used for calculating the
dew point with silent cooling.
Indicates if a request for cooling has been made
Displays the current domestic hot water set temperature
Displays the measured domestic hot water temperature. This
temperature is the controlled variable for DHW preparation.
Indicates if a request for domestic hot water has been made. Even
if there is a request for swimming pool water, it is possible that the
heat pump will not operate (e.g. because of the utility company
shut-off time). An HP block combined with a sufficiently high
cylinder temperature is indicated by "Bivalent-renewable".
Displays the heating controller software version including the boot
and bios version, as well as the valid network address.
Selecting the history menu item with the arrow buttons and
confirming with the ENTER button
Depending on the system configuration, the following data is
available:
Display of runtimes and stored data
Total runtime of 2nd heat generator
Runtime of the compressor in cooling operation
Total runtime of the hot water circulating pump
8.3
Display
Cooling function
Silent cooling
Cooling function
Cooling operation
Domestic hot
water
Sensors
Domestic hot
water
Sensors
Domestic hot
water
Always
Display
Bivalent or mono
energy
Reversible HP
Domestic hot
water
E-7